Availability: 100 in stock
  • Enclosure Rating: Nema 4 12 13 3R
  • UL Listed Assembly: Yes
  • Input Voltage: 460-480V
  • Model: CMC 22-32-480N4-DOL
  • MPN: CMC 22-32-480N4-DOL
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Brand: Elimia
  • Country/Region of Manufacture: United States
  • Restocking Fee: 10%
  • Overload Trip Rating: 22-32 Amps
  • NEMA Rating: NEMA 4
  • Condition: New
  • Return shipping will be paid by: Buyer
  • HP Rating: 20 HP @ 480V
  • Enclosure Type: Enclosed
  • Refund will be given as: Money Back

    Description

    Elimia Combination Motor Controller, Type F.
    Combination Motor Controllers (CMC) provide extra protection in a compact motor starter unit plus higher kA ratings. By using the adapter with the door mounted disconnect handle CMC's are a huge benefit overall versus standard combination motor starters. And meet requirements for NEC of local lock out tag out disconnect.
    Our assemblies are using S. Korean made LSis Manual Motor Starters with LSis contactors.
    Pre-wired for easy installation in a Heavy Duty Nema 4 steel enclosure.
    Equipped with Nema 4X A600 push button switches made by WEG.
    UL508A certified by Elimia.  Assembly is designed, built and shipped from Alabama, USA
    General Specifications:
    Adjustable thermal release
    Magnetic release is 13 Ie max
    Trip class 10
    Protective function: phase failure; short circuit; overload
    Please note that the label on the pictured unit may be from a different rated unit.  Use the specifications below to verify for your application.
    Please call us if you have any questions. We want you to get the right equipment - 1-855-4Elimia.  We offer an extensive line of standard motor starters as well as custom built units.  Combination starters and reversing starters are also available in standard and custom configurations.
    This new magnetic motor starter is designed to run equipment where the user controls the starting and stopping. It uses momentary push buttons and a latch auxiliary contact on the starter to hold power until the stop button is pressed. This type of controls can not be used for equipment such as an air compressor.
    Model Specifications:
    Model Number: CMC 22-32-480N4
    Model Explanation:
    CMC = Combination Motor Controller
    22-32  = Thermal Overload Adjustment Range
    480 = Coil Voltage (460-480V)
    N4 = Steel Nema 4 hinged enclosure
    Enclosure Size 12x12x8 inches nominal.
    Magnetic trip release 416A.
    AC-3 rated 20kA @ 460V.
    Contactor rating is 20HP @ 480V, Nema size 2.
    Sized for 20 HP @ 480V 3 phase.
    In our ongoing effort to provide high quality, low cost products with as little as possible Chinese content - this assembly contains approximately 20% China material. Here is the major content country of origin:
    Contactor - LSis Korea
    Overload - LSis Korea
    Enclosure - USA, Canada, Taiwan and/or China
    Switches - Weg Brazil
    Assembly - Elimia United States Alabama
    To size your starter properly you must determine the following:
    -Three phase or Single phase
    -Supply voltage ie. 120V; 208V; 230V; 460V; 600V
    -Machine single motor HP
    -Motor FLA (full load Amps) and worst case SFA (service factor Amps)
    -Application, what type of machine you running
    The control voltage is the voltage used to activate the coil of the contactor. In the simplest install you will want a coil voltage the same as your power supply. But is some cases you might want the control voltage to be different for a host of reasons. The this set up the control voltage is aquired using two legs of the input main voltage.
    The overload will have an adjustable Amperage range. Your overload choice is based on your machines FLA. If your machine motor has a FLA of 10 Amps at your supply voltage then you should choose the overload where 10 Amp falls within the adjustable range. For a 10 Amp FLA we would recommend overload 9 - 13 Amps. Some folks size overloads based on FLA times the Service Factor. So, if your service factor is 1.15, your SFA is 1.15 x FLA. In the example above it equals 10 FLA X SFA = 11.5 Amps.
    The overload of the CMC is reset using the disconnect handle on the door of the enclosure.
    Components mounted on a easy to remove back plate.
    90 day replacement Elimia warranty.
    Great price!
    We offer all kinds of electrical control panels including VFD and PLC control panels.
    Please call 1-855-4Elimia for more info or if we can help sizing a starter.
    Elimia has assembled and supplied thousands of starters to customers all over the world. In addition to our standard products we design and built custom control panels, VFDs, PLCs, container electrical systems, motor control centers etc... Our customers come back again and again for the value products we offer.
    Guarantee: Satisfaction Guaranteed! If you are not happy with your purchase within two weeks of arrival you can return it. No restocking fee! Offer excludes shipping and eBay fees. If the item has been installed and it turns out not be what you needed please call us. We will work with each customer and try to reach a resolution.
    There is no charge for on-sight pickup but 9% tax applies.
    Please note: All items should be professionally inspected and tested prior to installation or use. We are not liable for damages, injuries or death relating to our products.
    Payments: We accept Paypal and Credit Card payments. Credit card payments are only accepted over the phone.
    We reserve the right to refuse payment from buyers registered in foreign countries or locations with non corresponding ship to addresses. Additionally, we reserve the right to refuse payment from any buyer which will feel is acting in a possible malicious manner.
    Feedback: Once you are satisfied with your purchase please leave us feedback. If you have any problem with the transaction or product, please contact us.